Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

plumbing - Boiler flue adapting to chimney vent pipe

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :plumbing - Boiler flue adapting to chimney vent pipe
  • Supply Capacity : 10 units/month :plumbing - Boiler flue adapting to chimney vent pipe
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Download 2022 Antec Hardware New - vbsw2601.myftp.info

    GWC - Gas Water Condensing Inspect boiler interior 1. DO NOT remove or tamper with these circulators. Locate the air inlet pipe no further than 12 inches from the center of the vent pipe. If pH is outside this range or inhibitor test kit indicates low level, the inhibitor level may not be sufficient to prevent corrosion.Get Price

  • Using abandoned chimney as plumbing chase for vent

    Sep 03, 2019 · There are no rules preventing a boiler from being fitted into a chimney flue. There are gas boilers available that can use a conventional flue, these include models by Kidd, Viessmann, Halstead and ACV. The installation using the existing chimney would not necessarily be cheaper than relocating the boiler though, if this is your concern.Get Price

  • venting boiler without a chimney - Plbg.com - Plumbing

    chimney The chimney has two flues. One flue is devoted to a wood burning stove. The other flue currently supports a boiler and a FHA furnace. The old boiler will be replaced with the new high-effieciency boiler, and the FHA furnace will be replaced …Get Price

  • Properly venting a Wei-McLain CGi-4E boiler into a flue

    Jan 31, 2010 · The venting problem was it goes into a flue along with a standard 50gal water heater. With my old boiler (an HE3), the 3" went into a 4" manifold that received the WH in a wye, and this worked fine. This new boiler is more powerful and they used just a Tee to connect the WH, now the boiler exhaust is coming out the WH hood.Get Price

  • The Ultimate Guide To 5 Types of Chimney Pipe: By The Pros

    Dec 30, 2021 · Class A chimney pipe has many names, often referred to as double-wall chimney pipe, triple-wall chimney pipe, all-fuel pipe, or insulated chimney pipe. Class A pipe is used to vent high-temperature exhaust released from wood, coal, and oil-burning appliances such as fireplaces, stoves, boilers, and furnaces.Get Price

  • sealing around flue - PlumbersForums.net

    Apr 01, 2013 · Hi guys Eon recently serviced system boiler located in converted garage now a room. Flue got damaged during renovation but replaced by gas safe engineer, however the whole around it wasnt sealed so you can feel a draft from the wall cavity. I …Get Price

  • DuraTech® 5"-8" - DuraVent

    5″-8″ DuraTech is a double-wall, all-fuel chimney system for use with wood stoves, fireplaces, furnaces, boilers, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas, and zero-clearance fireplaces that are factory-built. Materials and Construction 5"-8" diameter pipe features inner wall of .020" 430 stainless Get Price

  • Boiler combustion venting - Plumbing & HVAC

    Jan 16, 2017 · As reported in the last issue of this magazine – some code officials have demanded that inlet air piping be identical to the vent piping. However, one Canadian boiler manufacturer's instructions read: "For the inlet air – four-inch Schedule 40 PVC, CPVC, ABS, or PPs piping of any type is permitted.". That clause is what the code Get Price

  • Venting a condensing boiler through chimney? — Heating

    Flue Vent Connectors - Heating Boilers, Furnaces, Water Heaters & Chimney Flues. A flue vent connector or "stackpipe" (orange in our sketch) is the term used to describe the round metal vent or connection pipe connected between the combustion gas exhaust port of an oil or gas fired heater or a wood or coal stove and the chimney that ultimately vents the combustion gases to …Get Price

  • Back to Basics: Venting for Gas-Fired Boilers | Kefid

    Apr 05, 2017 · When the chimney is removed in the future I will have a path to get the vent up into the attic and tie it in with the 4" vent stack. I always prefer to vent to atmosphere vs using an aav. This utility sink was a bit of an afterthought in full disclosure. Sounds like I'll aav it until I can remove the chimney in the future.Get Price

  • Venting high-efficiency boilers into masonry chimneys

    Flue Vent Connectors / Stackpipes for Heating Boilers Get Price

  • Boiler Flues - Ultimate Guide with Boiler Flue Regulations

    Nov 05, 2019 · If you've got a boiler at home, it's highly likely that you've also got a boiler flue. Boiler flues are fitted when using combi, regular, and system boilers. The only exception that may apply to a small number of homeowners is a back boiler. This is a type of boiler that is fitted behind a fireplace. If you have a gas boiler behind your fire, the emissions will exit through your …Get Price

  • Flue Vent Connectors / Stackpipes for Heating Boilers

    Flue Vent Connectors / Stackpipes for Heating Boilers Get Price

  • Condensing boilers - Venting thru existing B-vent chimney

    Common venting for condensing boiler is not allowed, unless it is a set designed as one boiler from the factory, like EVO boilers. You can run 2 sets of chimney kits, providing they have support every 5', and those vent kits have these supports. vents can be run together, only one limit is distance from exhaust to fresh air intake.Get Price

  • Venting problems for condensing boiler | Terry Love

    Jan 06, 2015 · Some of you may have read or responded to an earlier post regarding my father's change from a 55 YO oil boiler to a new gas boiler. Thanks for the responses. I was talking to a contractor yesterday who told me that they can not vent the flue gas out a plastic vent inserted into the existing chimney.Get Price

  • Centrotherm Innoflue Pipe & Parts - PexUniverse

    Centrotherm Innoflue. Centrotherm Innoflue polypropylene Single Wall (SW), Flex and Concentric vent pipe, fittings and accessories for residential & commercial natural gas and propane-fired boilers, water heaters and furnaces. UL 1738 listed and approved for Category IV (power vented, condensing) appliances.Get Price

  • How do I fill a hole surrounding a boiler flue? - Home

    The flue for my boiler has a large hole around it, presumably from when it was put in. I'd like to fill it in because it's unsightly, but in not sure of the best way to do it, as it's a large hole and near a boiler. Boiler flue adapting to chimney vent pipe. Hot Network QuestionsGet Price

  • Venting Gas BOiler through existing Chimney - DIYnot …

    May 01, 1999 · Some high-efficiency appliances allow the use of plastic pipe for venting gases, and many induced-draft high-efficiency appliances can be vented through an outside wall. However, if an outside wall is inaccessible, most manufacturers offer alternatives for venting through an existing chimney. In these cases, the plastic pipe or flue liner must extend the full …Get Price

  • Back to Basics: Venting for Gas-Fired Boilers | Kefid

    Jun 04, 2003 · A Category I vent system works by allowing heated flue products to rise vertically, so the vent pipe must rise vertically from the boiler vent connection as soon as possible. You should also limit the length of the horizontal flue pipe. All horizontal runs of vent pipe must rise 1/4 inch per foot of run to maintain proper draft in the vent.Get Price

  • Venting of Flue Gases - Mass.gov

    Re: venting boiler without a chimney. Author: packy (MA) if you run a "B" vent chimney, all the way from the heater, your horizontal run can be of the vertical height. if only the vertical chimney is "B" vent, any horizontal flue piping can be no more than 50% of that height. Post Reply. Re: venting boiler without a chimney.Get Price

  • plumbing - Boiler flue adapting to chimney vent pipe

    Oct 12, 2021 · Show activity on this post. I would convert to the 6" "B" vent asap and carry it to the chimney connection. As far as the type of pipe to be used for the boiler connections, which was your next question, that should be schedule 40 (standard black pipe). Where you connect the copper to the black steel pipe I would use dielectric unions.Get Price

  • System 636® Flue Gas Venting - IPEX Inc

    The use of plastic venting systems on gas fired water heaters, furnaces and boilers has undergone a significant change. CSA B149.1 Natural Gas and Propane Installation Code now requires all special venting material to be certified to ULC S636 across Canada. IPEX addressed this market need with System 636, a fully certified flue gas vent system.Get Price

Discount
7X24 Online