Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.
We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.
The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence
Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
New Boiler - Water dripping from flue
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Jan 05, 2022 · There are regulations in relation to the angel that the flue is installed at to protect from any water or chemical droplets formed within the pipe from dripping back into the boiler. Should the boiler flue be installed on a ground floor wall, a protection cover must be installed such as a grill or metal box.Get Price
Oct 04, 2021 · Dripping water from boiler flue. Reply Reply Author. Discussion. gmaz. Original Poster. 3,776 posts. 183 months Sunday 15th November 2020 What's New My Profile Get Price
Sep 03, 2019 · Since moving into the house 18 months ago there has been occasional water dripping from where the flue pipe enters the chimney. It seems to be coming down the chimney hitting the bottom plate then dripping down around the flue pipe. The chimney is I believe fitted with a circular clay liner (house same age as the boiler).Get Price
May 14, 2010 · The water is coming from the top of the boiler where the flue enters it, and runs down the front of the boiler, we can see this when we take the cover off, but the main drips are on the opposite side from the condense pipe, so I don't think its the condensing pipe, but mayb the u shape white plastic pipe the runs from the top of the boiler and Get Price
So in a panic, they shut down the boiler and called JSL Heating. Because it was a potential gas issue, we arrived as quickly as we could and began examining the boiler. The smell of gas is actually added in as a safety feature because gas itself is odourless. So what they were smelling was the unburnt chemical that was coming from the flue.Get Price
Oct 02, 2020 · If water is dripping from one of the pipe joins, dry the area around the join and double-check that the water is coming from it. If so, tighten the fitting a little and see if it stops. For a very small boiler leak repair, you may be able to treat your central heating system with additives that automatically form a seal.Get Price
2018 new boiler flue through roof. heat recovery boiler agent flue gas. vertical flue fire tube boiler structure. horizontal multistage steam boiler flue. water dripping heavily from boiler flue diynot. 106 natural gas boiler flue gas recirculation. dg generator flue gas heat recovery boiler supplier.Get Price
Dec 20, 2005 · No drips at all from flue. The flue should have a slight incline back to the boiler of usually around 3% of the flues length. The steam vapour you mention is what we call "PLUMING" and is due to the flue gas temperature being close to dew point. (approx 56 degree's) If your boiler is pluming it's running efficiently.Get Price
Aug 10, 2007 · New Boiler - Water dripping from flue!! - .ultimatehandyman.co.uk. Ultimate Handyman Forum Index DIY Forum/Home improvement Plumbing Forum Central Heating & Boilers. It is currently Mon Feb 07, 2022 2:04 am. All times are UTC.Get Price
May 19, 2019 · I was round a friends today and noticed water dripping from the boiler flue joints. She has no idea how long its been dripping, but Id guess for a while judging by the marks on the flue. Its a Vallient EcoTec pro 28 combi boiler. A quick search suggests it could be the angle of the flue is wrong Get Price
Water Dripping Heavily From Boiler Flue | DIYnot ForumsGet Price
Question 1, Boiler Flue dripping. — MoneySavingExpert ForumGet Price
Jun 29, 2017 · Modern condensing boilers should have a rising flue. That looks towards the steeper end of the scale. Any water that gets in should run back down and through to the condensate trap.Get Price
Jan 01, 2010 · The more obvious risk however is the risk of water dripping onto the electrics of the boiler – which was the case until I spotted it. To add to this a large section of the easterly facing wall in the sitting room area has water stains on it where the water has clearly leaked in through the plaster and block work.Get Price
A boiler might also be leaking water due to corrosion. Air in the heating system will corrode copper pipes, radiators and tanks over time resulting typically in debris in the heating system, this corrosion can cause them to weaken and eventually crack. This is a common issue even in the most modern boilers and can usually be identified by water Get Price
Mar 09, 2010 · The flue on a condensing boiler should, in a perfect world, slope back towards the boiler at 3 degrees. You may still get a very slight discharge of condensate when the boiler fires up as the fan may 'blow out' any residual condensate drops that my be laying in the flue. Boilers can produce around 2 litre/hr if in full condensing mode.Get Price
Apr 09, 2018 · Hey Folks! I have a thorny issue with a flue installed at the same time as a new ecotec boiler about a year ago. I noticed a couple of months ago that it was leaking from two of the connector joints connecting the extension pieces of the flue together.Get Price
— MoneySavingExpert ForumHi, My boiler flue keeps dripping water, the amount depends on the temp outside.New Boiler - Water dripping from flue!! — MoneySavingExpert Forum10 Aug 2007 Hi, I've had a boiler fitted (combi condensing) and have noticed occasionaly, there are water droplets coming the flue pipe - just after the steam vapour this Get Price
Aug 10, 2007 · New Boiler - Water dripping from flue!! - .ultimatehandyman.co.uk. Ultimate Handyman Forum Index DIY Forum/Home improvement Plumbing Forum Central Heating & Boilers. It is currently Mon Feb 07, 2022 2:04 am. All times are UTC.Get Price
These boiler flue distance regulations help to ensure that harmful gases are fully expelled from your property. The exact distance will depend on the size of your home but, generally, the regulations prevent a boiler flue from being situated within 30-60cm of a window or door. This is to prevent harmful gases from exiting the flue and then re Get Price
Sep 03, 2019 · I have a recently installed (2 months ago) Ariston Aco condensing boiler installed in my kitchen. I have just noticed that there are drips of water forming on the bottom lip of the flue and when the hot water tap is turned on and the boiler kicks in a fairly heavy stream of drips lasting about 3 seconds comes out and then it continues to drip slowly again once every few …Get Price
Sep 03, 2019 · Since moving into the house 18 months ago there has been occasional water dripping from where the flue pipe enters the chimney. It seems to be coming down the chimney hitting the bottom plate then dripping down around the flue pipe. The chimney is I believe fitted with a circular clay liner (house same age as the boiler).Get Price
Apr 13, 2013 · The way it has discolored the bricks and damaged the concrete it probably not just water. It looks like the liquid is leaking from the small …Get Price
Mar 07, 2009 · If so, the moisture in the flue gases should be condensed out (hence its name) and very likely some of it will drip out t'end of flue. Most of the condensate in the flue should trickle back into the boiler where it is taken care of via a condensate pipe. But the odd drip at the flue outlet shouldn't be a problem.Get Price
A boiler leaking water needs the urgent attention of a heating engineer as it could lead to serious damage. Corroded pipes, high pressure and loose joints are all common causes of a boiler leaking water. If your boiler was only installed recently, the leak could be …Get Price
Leaking Worcester Bosch https://.youtube.com/watch?v=_4gDnlmliQItoday we are looking at a leaking worcester bosch combi boiler you will need a gas safe enGet Price
Oct 20, 2008 · There will always be some water dripping from the end. tho', as the condensate forms droplets there. The other flues you've looked at nearby might not be from condensing boilers, so won't be producing this plume (or, rather, it fires all the steam out well in to the air!). devil's advocate, Oct 19, 2008. #5.Get Price
Aug 11, 2007 · The flue on a condensing boiler is supposed to pass thru the wall with the angle of the fall running back towards the boiler so that condense created by the boilers operation is collected in the boiler before being discharged. It sounds like the flue has been set to fall in the opposite direction hence the effect you explain. Hope This HelpsGet Price
Sep 03, 2019 · No. It's a non-opening window. Boiler is fitted understairs. I posted the picture merely to demonstrate that condensing flues,even correctly installed ones, can appear to drip. Strictly speaking the icicles are not caused by dripping from the flue in this case but by the pluming passing through the terminal guard,which then drips.Get Price
Question 1, Boiler Flue dripping. — MoneySavingExpert ForumGet Price